Oxy 1 Hyperbaric Oxygen Chamber (HBOT, Single)
A single-seat hard-shell chamber offered at 1.5 ATA or 2.0 ATA, with a 10 L/min oxygen flow, custom colours and an optional red-light version.
Single-seat hyperbaric oxygen chamber offered at 1.5 ATA or 2.0 ATA, with a 10 L/min oxygen flow, custom colours and an optional red-light version.
Architectural Design & Therapeutic Intent
The Oxy 1 is a single-seat hyperbaric oxygen chamber offered in two pressure ratings: 1.5 ATA and 2.0 ATA. Both use a 10 L/min oxygen flow, and colours can be customised.
The 1.5 ATA model measures 1400 × 800 × 1900 mm externally. The 2.0 ATA model is a compact single-person hard-shell setup whose dimensions vary by configuration. A red-light version is available for both ratings.
This product requires a regulatory check and a trained operator.
Single-Seat Pressurised Chamber
A hard-shell single-seat chamber supplied with oxygen at a 10 L/min flow, available at two pressure ratings.
- 1Pressure rating of 1.5 ATA or 2.0 ATA.
- 2Oxygen flow of 10 L/min.
- 3Hard-shell single-seat build.
- 4Optional red-light version.
Engineered Capabilities & Advanced Controls
Two Pressure Ratings
Choose 1.5 ATA or 2.0 ATA.
Compact Single Seat
Hard-shell chamber for one person.
Custom Colours
Colours can be customised.
Red-Light Option
A red-light version is available.
Evidence-Based Biological Benefits
Flexible Specification
Two pressure options to match the site.
10 L/min Oxygen Flow
For a single seat.
Full Technical Specifications
Models Specifications5 Parameters Calibrated
Turnkey Delivery & Included Components
Recommended Session Protocols
Calibrated to maximize therapeutic outcome without triggering biological exhaustion.
Cumulative regenerative benefits compound with consistent weekly integration.
- •Hyperbaric chambers must only be installed and operated in line with local regulations, by a trained operator, following the manufacturer's safety procedures.
- •Not suitable for everyone. A medical professional should confirm that a person is suitable before any session.
Step-by-Step Operator & User Procedure
Pre-Session Checklist
- Confirm local regulatory requirements are met and the operator is trained.
- Check the safety valves, emergency switch and intercom before every session.
Session Execution Steps
Run the operator's safety checklist and confirm the user is suitable.
Pressurise gradually and monitor via the intercom and control panel.
Release pressure at the controlled rate before opening the door.
Turnkey Facility Integration
Longevity & Wellness Centres
A supervised pressurised-cabin service within a wellness menu.
Clinics (where regulations permit)
Installed and operated only in line with local requirements.